VNENSign in
Posted date: 2-Feb-2026 11:32:09 AM VN
Summary of Violations and Penalties under

Decree No. 106/2025/NĐ-CP⚠️ - Acts and fines in the field of fire prevention and fighting apply from July 1, 2025

Effective date: 01-Jul-2025
💡 Acts subject to penalties shall be regarded as prohibited or mandatory acts.
Behavior and Penalties
(Articles 6-28)
ViolationMinimum penalty (VND)Maximum penalty (VND)
Damaging banners, slogans, billboards, posters, and pictures promoting fire prevention, firefighting, rescue, and relief. (Article 6.1)300,000500,000
Failure to organize propaganda, dissemination, and education on knowledge and laws regarding fire prevention, firefighting, and rescue for the subjects specified in Article 8 of the Law on Fire Prevention, Firefighting, and Rescue. (Article 6.2)1,000,0003,000,000
Failure to organize annual professional training in fire prevention, firefighting, rescue, and relief for the subjects specified in points c, d, e, f, and g of Clause 1, Article 45 of the Law on Fire Prevention, Firefighting, Rescue, and Relief who have already received professional training in fire prevention, firefighting, rescue, and relief. (Article 6.3)4,000,0006,000,000
Using the subjects specified in points d, e, f and g of Clause 1, Article 45 of the Law on Fire Prevention, Firefighting and Rescue to perform fire prevention, firefighting, rescue and relief tasks without having received professional training in fire prevention, firefighting, rescue and relief. (Article 6.4)6,000,0008,000,000
Issuing fire prevention, firefighting, rescue, and emergency response regulations that lack sufficient content as prescribed or are not suitable for the characteristics and nature of the facility's operations or transportation vehicle; Posting regulations, signs, prohibition signs, and directional signs regarding fire prevention, firefighting, rescue, and emergency response in locations other than those prescribed. (Article 7.1)1,000,0003,000,000
Failure to maintain regulations, signs, prohibition signs, and directional signs regarding fire prevention, firefighting, rescue, and emergency response that have been posted. (Article 7.2)4,000,0006,000,000
Failure to issue or post regulations, signs, prohibition signs, and directional signs regarding fire prevention, firefighting, rescue, and emergency response. (Article 7.3)6,000,0008,000,000
Establishment of a basic fire prevention, firefighting, and rescue team, or a specialized fire prevention, firefighting, and rescue team that does not meet the prescribed number of personnel; Agencies and organizations operating within the facility do not send personnel to participate in the basic fire prevention, firefighting, and rescue team. (Article 8.1)3,000,0005,000,000
No assignment of personnel to perform fire prevention, firefighting, rescue, and relief duties at facilities under fire prevention and firefighting management with fewer than 20 regularly employed personnel; No provision of a fire prevention, firefighting, rescue, and relief duty station for the facility's fire prevention, firefighting, and rescue team, or the specialized fire prevention, firefighting, and rescue team. (Article 8.2)6,000,0008,000,000
No deployment of personnel and equipment of the grassroots fire prevention, firefighting and rescue team, or specialized fire prevention, firefighting and rescue team for daily firefighting, rescue and relief operations. (Article 8.3)8,000,00010,000,000
No establishment of a fire prevention, firefighting and rescue team at the facility. (Article 8.4)10,000,00020,000,000
No specialized fire prevention, firefighting, and rescue team will be established. (Article 8.5)20,000,00030,000,000
Insufficient documentation in the fire prevention, firefighting, rescue, and relief file. (Article 9.1) | 1,000,000 | 3,000,000 |
| Failure to create records regarding fire prevention, firefighting, rescue, and relief. (Article 9.2) | 5,000,000 | 7,000,000 |
| Failure to submit fire prevention, firefighting, rescue, and emergency response documents for fire prevention and firefighting inspection; Failure to submit reports on the results of fire prevention, firefighting, rescue, and emergency response work of the facility within the prescribed timeframe; Failure to implement fire prevention, firefighting, rescue, and emergency response requirements in the written recommendation for the facility to rectify existing shortcomings and limitations. (Article 10.1) | 3,000,000 | 5,000,000 |
| Failure to assign authorized personnel to work with authorized inspectors after receiving notification of fire safety inspection; Failure to submit reports on the results of fire safety, firefighting, rescue, and relief work at the facility. (Article 10.2) | 5,000,000 | 10,000,000 |
| Failure to conduct periodic fire safety inspections. (Article 10.3) | 10,000,000 | 20,000,000 |
| Failure to comply with the temporary suspension of operations as stipulated in the administrative penalty decision in the field of fire prevention, firefighting, and rescue issued by the competent authority; Failure to comply with the decision to temporarily suspend or suspend operations as prescribed by the law on fire prevention, firefighting, and rescue. (Article 10.4) | 20,000,000 | 30,000,000 |
Using sources of fire, heat, equipment, or tools that generate fire or heat without ensuring the required fire prevention and firefighting distance. (Article 11.1) | 5,000,000 | 10,000,000 |
| Using open flames, heat sources, equipment, or tools that generate fire or heat in areas where it is prohibited; Welding or cutting metal without fire prevention and firefighting measures as prescribed. (Article 11.2) | 20,000,000 | 25,000,000 |
| Installation and use of electrical wires, electrical equipment, switching and protective devices that do not ensure fire safety. (Article 12.1) | 6,000,000 | 8,000,000 |
| Failure to maintain the installed explosion-proof electrical equipment. (Article 12.2) | 10,000,000 | 15,000,000 |
| Failure to equip, install, or use explosion-proof electrical equipment. (Article 12.3) | 20,000,000 | 25,000,000 |
| No fire prevention measures for the indoor charging area for electric motor vehicles; No electrical system for fire prevention and firefighting; No maintenance of a power supply for fire prevention and firefighting. (Article 12.4) | 40,000,000 | 50,000,000 |
| Failure to conduct regular inspections and maintenance of the grounding and lightning protection system. (Article 13.1) | 1,000,000 | 3,000,000 |
| Installation of grounding and lightning protection systems not in accordance with regulations; Failure to maintain installed grounding and lightning protection systems. (Article 13.2) | 10,000,000 | 15,000,000 |
| Failure to install grounding and lightning protection systems for houses and buildings. (Article 13.3) | 20,000,000 | 25,000,000 |
| Arranging or storing hazardous substances and goods that are flammable or explosive in violation of regulations; Storing hazardous substances and goods that are flammable or explosive in excess of the prescribed quantity or weight. (Article 14.1) | 3,000,000 | 5,000,000 |
| Storing or using hazardous substances or goods that are flammable or explosive in locations other than those designated. (Article 14.2) | 5,000,000 | 10,000,000 |
To create a hazardous fire and explosion environment where the fire and explosion hazard index exceeds the lower limit of the flammability concentration limit. (Article 14.3) | 10,000,000 | 15,000,000 |
| Illegally possessing flammable or explosive hazardous substances and goods, but not to the extent of incurring criminal liability. (Article 14.4) | 20,000,000 | 25,000,000 |
| Illegally using substances or goods that are hazardous in terms of fire and explosion, but not to the extent of incurring criminal liability. (Article 14.5) | 45,000,000 | 50,000,000 |
| Failure to maintain the installed equipment for detecting leaks of flammable and explosive hazardous materials and goods; Failure to maintain the installed anti-static equipment and systems. (Article 15.1) | 3,000,000 | 5,000,000 |
| Failure to equip or install equipment for detecting leaks of flammable and explosive hazardous substances and goods; Failure to equip or install anti-static equipment and systems. (Article 15.2) | 10,000,000 | 15,000,000 |
| Transferring, decanting, or filling hazardous substances and goods that are flammable or explosive in locations other than those designated; Transferring, decanting, or filling hazardous substances and goods that are flammable or explosive into containers that are of the wrong type or unsuitable for the type of hazardous substance or goods. (Article 15.3) | 20,000,000 | 25,000,000 |
| Illegally producing or trading hazardous substances or goods that pose a fire or explosion risk, but not to the extent of incurring criminal liability. (Article 15.4) | 40,000,000 | 50,000,000 |
| Arranging and storing flammable and explosive hazardous materials and goods on transport vehicles without ensuring fire safety. (Article 16.1) | 3,000,000 | 5,000,000 |
| Failure to maintain fire safety conditions of vehicles when transporting flammable and explosive hazardous substances and goods; Transporting other goods together with flammable and explosive hazardous substances and goods that are not permitted on the same vehicle; Carrying unauthorized persons on vehicles transporting flammable and explosive hazardous substances and goods. (Article 16.2) | 5,000,000 | 7,000,000 |
| Failure to comply with fire safety regulations when loading, unloading, pumping, or transferring flammable and explosive substances and goods from vehicles; Failure to maintain fire safety measures for equipment and pipelines transferring flammable and explosive gases and liquids; Loading, unloading, pumping, or transferring flammable and explosive substances and goods at locations that do not ensure fire safety. (Article 16.3) | 20,000,000 | 25,000,000 |
| Purchasing mandatory fire and explosion insurance at an incorrect premium rate compared to the regulations for facilities required to purchase mandatory fire and explosion insurance; Paying between 50% and less than 100% of the total amount allocated for fire prevention, firefighting, rescue, and relief activities from mandatory fire and explosion insurance as prescribed. (Article 17.1) | 10,000,000 | 15,000,000 |
| Paying less than 50% of the total amount allocated for fire prevention, firefighting, rescue, and relief activities from mandatory fire and explosion insurance as prescribed. (Article 17.2) | 20,000,000 | 30,000,000 |
| Failure to purchase mandatory fire and explosion insurance for facilities with fire and explosion hazards classified as Group 2 according to the law on fire prevention, firefighting and rescue. (Article 17.3) | 30,000,000 | 40,000,000 |
| Failure to purchase mandatory fire and explosion insurance for facilities with fire and explosion hazards classified as Group 1 according to the law on fire prevention, firefighting, and rescue; Failure to pay the amount allocated for fire prevention, firefighting, rescue, and relief activities from mandatory fire and explosion insurance as prescribed. (Article 17.4) | 40,000,000 | 50,000,000 |
| Conversion, addition of function, or renovation of buildings or building components during use that are subject to fire safety design appraisal when there is no fire safety design appraisal document from the specialized management agency; Modification of vehicles during use that are subject to fire safety design appraisal when there is no fire safety design appraisal document from the specialized management agency. (Article 18.1) | 15,000,000 | 20,000,000 |
| Construction of works, project components or manufacturing, assembly, and new construction of vehicles subject to fire safety design review without a fire safety design review document from the specialized management agency. (Article 18.2) | 20,000,000 | 25,000,000 |
| Putting into operation or use a construction project, project component, or transportation vehicle that has had its design approved or its design assessed for fire prevention and fighting without a written approval of the fire prevention and fighting acceptance test results from the specialized management agency. (Article 18.3) | 30,000,000 | 50,000,000 |
| Putting into use or operation works, project components, or vehicles subject to fire safety design review without a fire safety design review document and a fire safety acceptance test approval document from the specialized management agency. (Article 18.4) | 40,000,000 | 50,000,000 |
| Erasing, altering, or falsifying the content of permits for the circulation of fire prevention, firefighting, rescue, and relief vehicles, fire-resistant materials, and fire-retardant components. (Article 19.1) | 20,000,000 | 30,000,000 |
| Conducting business, putting fire prevention, firefighting, rescue, and relief equipment, fire-resistant materials and components into circulation without a license; Using false documents to request a license for the circulation of fire prevention, firefighting, rescue, and relief equipment, fire-resistant materials and components. (Article 19.2) | 40,000,000 | 50,000,000 |
| Equipped with common fire-fighting equipment and rudimentary demolition tools that do not comply with regulations. (Article 20.1) | 1,000,000 | 2,000,000 |
| Lack of standard fire-fighting equipment and rudimentary demolition tools. (Article 20.2) | 3,000,000 | 5,000,000 |
| Equipment and installation of emergency lighting, escape route signs not in accordance with regulations. (Article 20.3) | 5,000,000 | 7,000,000 |
| Equipment for fire prevention, firefighting, rescue, and relief for the basic fire prevention, firefighting, and rescue team and the specialized fire prevention, firefighting, and rescue team does not meet the regulations. (Article 20.4) | 8,000,000 | 10,000,000 |
| Failure to equip or install emergency lighting, escape route signs, or other lighting equipment. (Article 20.5) | 10,000,000 | 15,000,000 |
| Failure to equip the Fire Prevention, Firefighting, Rescue, and Salvage Team with fire prevention, firefighting, and rescue equipment. (Article 20.6) | 15,000,000 | 20,000,000 |
| Failure to equip specialized fire prevention, firefighting, rescue, and relief teams with fire prevention, firefighting, and rescue equipment. (Article 20.7) | 20,000,000 | 25,000,000 |
| Equipment and installation of fire alarm systems not in compliance with regulations; Equipment and installation of fire extinguishing systems not in compliance with regulations. (Article 20.8) | 30,000,000 | 40,000,000 |
| Failure to equip or install a fire alarm system; Failure to equip or install a fire extinguishing system; Failure to equip with motorized fire fighting, rescue, and relief equipment. (Article 20.9) | 40,000,000 | 50,000,000 |
| Unauthorized movement or obstruction of fire prevention, firefighting, rescue, and emergency response equipment that has been installed. (Article 21.1) | 1,000,000 | 3,000,000 |
| Failure to maintain sufficient quantity or ensure the quality of commonly used firefighting equipment and rudimentary demolition tools that have been equipped and installed. (Article 21.2) | 3,000,000 | 5,000,000 |
| Failure to maintain the operation of installed emergency lights, lighting equipment, and escape route signs; Failure to maintain the operation of installed independent fire alarm systems. (Article 21.3) | 5,000,000 | 10,000,000 |
| Failure to maintain the operation of fire alarm system equipment that has been installed; Failure to maintain the operation of fire extinguishing system equipment that has been installed. (Article 21.4) | 10,000,000 | 20,000,000 |
| Do not deploy motorized firefighting, rescue, and relief vehicles for firefighting, rescue, and relief operations. (Article 21.5) | 20,000,000 | 25,000,000 |
| Failure to maintain the operation of the installed fire alarm system; Failure to maintain the operation of the installed fire extinguishing system. (Article 21.6) | 40,000,000 | 50,000,000 |
| Failure to maintain and service common fire extinguishing equipment or independent fire alarm systems; Failure to maintain and service fire alarm systems in accordance with regulations; Failure to maintain and service fire extinguishing systems in accordance with regulations; Failure to maintain and service motorized fire extinguishing, rescue, and relief equipment in accordance with regulations. (Article 22.1) | 3,000,000 | 5,000,000 |
| Failure to maintain and service motorized firefighting, rescue, and relief vehicles. (Article 22.2) | 5,000,000 | 10,000,000 |
| Failure to maintain the fire alarm system; Failure to maintain the fire extinguishing system. (Article 22.3) | 10,000,000 | 20,000,000 |
| Equipment and installation of the smoke exhaust ventilation system do not comply with regulations; Equipment and installation of the system for creating excess pressure for the area requiring smoke protection do not comply with regulations. (Article 23.1) | 10,000,000 | 20,000,000 |
| Failure to maintain natural ventilation or the installed smoke exhaust ventilation system; Failure to maintain the installed excess pressure system for the area requiring smoke protection. (Article 23.2) | 20,000,000 | 25,000,000 |
| Failure to maintain ventilation solutions for areas where hazardous substances and goods that are flammable or explosive are produced, stored, traded, or used. (Article 23.3) | 30,000,000 | 40,000,000 |
| No natural ventilation or smoke exhaust ventilation solution; No provision or installation of a pressure relief system for the area where such a system is required. (Article 23.4) | 40,000,000 | 50,000,000 |
Install mirrors on escape routes; Doors on escape routes must not open in the direction of escape. (Article 24.1) | 1,000,000 | 3,000,000 |
| To obstruct escape routes or escape paths with materials, goods, vehicles, equipment, or other devices. (Article 24.2) | 5,000,000 | 10,000,000 |
| Failure to maintain doors installed on escape routes or escape paths; Locking doors installed on escape routes or escape paths. (Article 24.3) | 10,000,000 | 15,000,000 |
| Failure to maintain escape routes or exit paths in a room or area; Insufficient escape routes or exit paths in a room or area. (Article 24.4) | 20,000,000 | 30,000,000 |
| Failure to maintain escape routes or escape paths in buildings or structures; Insufficient escape routes or escape paths in buildings or structures. (Article 24.5) | 40,000,000 | 50,000,000 |
| Leaving materials, goods, vehicles, equipment, and other items that do not meet fire safety distance requirements. (Article 25.1) | 2,000,000 | 4,000,000 |
| Failure to maintain the fire-resistant partition that has been constructed and installed, except for the acts specified in Clause 5 of this Article. (Article 25.2) | 5,000,000 | 7,000,000 |
| Failure to remove flammable materials from the safety corridor of oil, gas, and petroleum product pipelines; Installation of flammable gas or liquid pipelines in unauthorized areas or areas not meeting fire safety requirements. (Article 25.3) | 8,000,000 | 10,000,000 |
| Failure to maintain fire safety distances between buildings and structures; Lack of fire barriers, except for the actions specified in Clause 5 of this Article. (Article 25.4) | 20,000,000 | 25,000,000 |
| No fire-resistant walls or partitions or fire-resistant floors are present or maintained. (Clause 25.5) | 30,000,000 | 40,000,000 |
| Construction of houses and buildings that do not ensure fire safety distances. (Article 25.6) | 40,000,000 | 50,000,000 |
| Developing a fire fighting, rescue, and relief plan for a facility or vehicle that does not meet the prescribed content; Failing to update, supplement, or revise the fire fighting, rescue, and relief plan for a facility or vehicle; Failing to approve or approving the fire fighting, rescue, and relief plan for a facility or vehicle without proper authority. (Article 26.1) | 3,000,000 | 5,000,000 |
| Failure to practice all scenarios in the fire fighting, rescue, and relief plan of the facility or vehicle; Failure to deploy sufficient personnel or resources under management to participate in the fire fighting, rescue, and relief plan practice of the Police agency when mobilized by the competent authority. (Article 26.2) | 5,000,000 | 10,000,000 |
| Failure to cooperate in developing fire fighting, rescue, and relief plans of the Police agency as requested by the competent Police agency; Failure to cooperate in participating in fire fighting, rescue, and relief plan drills of the Police agency as requested by the competent Police agency. (Article 26.3) | 10,000,000 | 15,000,000 |
| Failure to conduct fire fighting, rescue, and emergency response drills for facilities and vehicles. (Article 26.4) | 15,000,000 | 20,000,000 |
| Failure to develop a fire fighting, rescue, and emergency response plan for the facility or vehicle. (Article 26.5) | 20,000,000 | 25,000,000 |
| Entering a fire fighting, rescue, or relief area without permission from an authorized person. (Article 27.1) | 500,000 | 1,000,000 |
| Failure to comply with orders or decisions to mobilize participation in firefighting, rescue, and relief operations by competent authorities; Failure to organize and implement measures to mitigate the consequences of a fire within the permitted conditions and capabilities. (Article 27.2) | 3,000,000 | 5,000,000 |
| Preventing or obstructing the reporting of fire, rescue, or emergency situations. (Article 27.3) | 5,000,000 | 10.00

ai-luatvietnam-icon-24 Change analysis